Logo Caen

A1519B

Obsolete

12 Channel Floating 250 V, 100 µA / 1 mA Board

Features

  • 12 independently controllable High Voltage channels
  • 250 V output; 1/0.1 mA dual current range
  • Individual floating channels
  • DB37 Multipin connectors
  • Low ripple
  • Under/over-voltage alert, overcurrent and max. voltage protection
  • Interlock logic for unit enable
  • Software Tool for easy channel management

Overview

The CAEN Mod.A1519B single width board houses 12 HV floating channels (i.e. the channels do not share any ground reference). The output voltage can be programmed and monitored in the range 0 ÷ 250 V with a 50 mV resolution. The floating channels allow on-detector grounding, thus avoiding ground-loops which may increase noise level. The Mod. A1519B offers 100 µA / 1 mA dual current range (selectable via internal jumpers).

If the output voltage differs from the programmed value by more than 3% of voltage full scale range, the channel is signalled to be either in OVERVOLTAGE or UNDERVOLTAGE condition. Moreover, for each channel, a voltage protection limit SVMAX can be fixed via software with 1 V resolution and the output voltage can not be programmed beyond this value.

The HV RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷ 50 V/s in 1 V/s steps.

The output current is monitored with 10 nA / 100 nA resolution depending on current range; if a channel tries to draw a current larger than its programmed limit it is signalled to be in OVERCURRENT condition; the SY1527 system detects this state as a fault and reacts according to the setting of the TRIP parameter, namely:

1) TRIP=infinite ( = 1000 s)

When the set output current value is reached the channel behaves like a constant current generator.

2) TRIP=finite (< 1000 s)

The output current keeps the set value only for programmed time interval and then is switched off.

The TRIP time (i.e. the maximum time an OVERCURRENT condition is allowed to last) can be programmed in 0.1 s steps.

The maximum output voltage (VMAX Hardware) can be fixed, through a potentiometer located on the front panel, at the same common value for all the board channels and this value can be read out via software.

The board is provided with an “HV EN” input that disables the channels when it is not connected to ground.

Technical Specifications

No. of Channels

12

Output Voltage

0÷250 V

Polarity

Floating

Max. Output Current
  • Low Range: 100 µA
  • High Range: 1 mA
Voltage Set Resolution

50 mV

Voltage Monitor Resolution

50 mV

Current Set Resolution

10 nA /100 nA depending on current range

Current Monitor Resolution

10 nA /100 nA depending on current range

VMAX hardware

0÷250 V common for all the board channels

VMAX hardware accuracy

± 2% of FSR

VMAX software

0-250 V settable for each channel

VMAX software resolution

50 mV

Ramp Up/Down

1÷50 Volt/sec, 1 Volt/sec step

Voltage Ripple

< 30 mV pp

Voltage Monitor vs. Output Voltage Accuracy

± 0.3% ± 0.2 V

Voltage Set vs. Output Voltage Accuracy

± 0.3% ± 0.1 V

Current Monitor vs. Output Current Accuracy
  • ± 2% ± 0.5 µA (1 mA range)
  • ± 2% ± 0.05 µA (100 uA range)
Current Set vs. Current Monitor Accuracy
  • ± 2% ± 0.1 µA (1 mA range)
  • ± 2% ± 0.01 µA (100 µA range)

Compare

Compare with High Voltage Power Supply.

Loading...

Accessories

A646
12 Channel DB37 to SHV connector Adapter (Max: 500 V - Desktop)

Ordering Options

Code Description
WA1519XAAAAA A1519B - SYx527 H.V. channels 250 V 1/0.1 mA floating (12 ch)  (Obsolete) RoHS

Contacts

Great to have you back!