• Skip to main content
  • Skip to footer
CAEN logo light
  • About
    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us
  • Products
  • Resources
    • Documentation
    • Download
    • FAQ
    • Glossary
    • Certifications
    • Legal and Compliance
  • Support
  • Contact
All productsSpecial OffersForm FactorDigital SpectroscopyCAEN SyS productsPower SupplyModular Pulse ProcessingDigitizer FamiliesEducationalFirmware & SoftwarePowered CratesAccessoriesBrands
Background image

A3100B

1 Channel 8 V / 100 A / 600 W Power Supply Board

Request a Quote Add to WishlistView Wishlist

Home Power SupplyEASY (Embedded Assembly SYstem)EASY3000 LV BOARDS A3100B

Photo of A3100B
DatasheetDownloadCompareTech. Spec.

Highlights

  • EASY Subsystem Power Supply Module

  • Magnetic field and radiation tolerant

  • One floating 2 ÷ 8 V /100 A channel

  • 600 W maximum output power

  • VMax and IMax set by trimmer for each channel

  • On/Off for each channel

  • Channels individually controlled and protected

  • Line Drop Regulation on board panel

  • Interlock capability

  • 48 V Service local and remote on/off

  • Screw Lock output connectors

Overview

The CAEN Mod. A3100B is a 8 V / 100 A Power Supply Board, developed for operation in magnetic field and moderate radioactive environment. One A3100B houses one floating (reversible polarity) 8 V / 100 A (600 W maximum output power) channel.
The connector output voltage range is 2 ÷ 8 V with 5 mV monitor resolution; channel control includes various alarms and protections.
The board is provided with Remote Sensing Lines to compensate for the voltage drop over the connection cables. If the output voltage differs from the programmed value by more than 3% of voltage full scale range, the channel is signalled to be either in Overvoltage and Undervoltage condition.
Moreover, for each channel, a voltage protection limit SVMAX can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value.

Brass Hexagon head bold connector

Brass hexagon head set screw, M6x30mm connector for A3100B

Consult our connectors reference page for technical information.

Safety features allows the module to perform as a current generator and includes:

Channels
can be enabled or disabled through the Global Interlock logic.
Overvoltage and Undervoltage warning when the output voltage differs from the programmed value by more than 3% of voltage full scale range.
Overcurrent detection When a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.
Hardware VMAX and IMAX
Maximum output voltage and maximum current value can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value.


Ordering Options

Code Description
WE3100BXAAAA

A3100B – EASY3000 L.V. channels 8 V/100 A/600 W floating – Bolt Conn. (1 ch)

You also may be interested in…

A3100

A3100

1 Channel 8 V / 100 A / 600 W Power Supply Board
A3100HBP

A3100HBP

1 Channel 8-14 V / 50 A / 600 W Power Supply Board
Download Compare Tech. Spec.

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist
Request a Quote

Request a Quote

    Submit

    Compare

    Close
    Image
    Name
    No. of Channels
    Connectors
    No. max of boards per crate
    Width (slots)
    Max power per channels
    Iset/Imon resolution
    Vset/Vmon resolution (mV)
    Current Full Scale (A)
    Voltage full Scale (V)
    Max Ripple (mVpp)
    A3009B

    A3009B

    12

    Screw lock connectors

    5

    4

    45 W

    10 mA

    5

    9

    2 ÷ 8

    20

    A3602

    A3602

    3

    DB37

    10

    2

    35 W

    10 mA

    5

    5

    2 ÷ 7

    5

    A3025B

    A3025B

    4

    Brass hexagon head bolt

    5

    4

    150 W

    100 mA

    5

    25

    2 ÷ 8

    10

    A3009

    A3009

    12

    APP 1317G4

    5

    4

    45 W

    10 mA

    5

    9

    2 ÷ 8

    20

    A3009H

    A3009H

    12

    APP 1317G4

    5

    4

    45 W

    10 mA

    5

    9

    6 ÷ 14

    20

    A3016

    A3016

    6

    APP 1317G4

    5

    4

    90 W

    10 mA

    5

    16

    2 ÷ 8

    20

    A3050B

    A3050B

    2

    Brass hexagon head bolt

    5

    4

    300 W

    100 mA

    5

    50

    2 ÷ 8

    10

    A3100

    A3100

    1

    APP PC5933T

    5

    4

    600 W

    100 mA

    5

    100

    2 ÷ 8

    10

    A3009HB

    A3009HB

    12

    Screw lock connectors

    5

    4

    45 W

    10 mA

    5

    9

    6 ÷ 14

    20

    A3050

    A3050

    2

    APP PC5933T

    5

    4

    300 W

    100 mA

    5

    50

    2 ÷ 8

    10

    A3025

    A3025

    4

    APP PC5933T

    5

    4

    150 W

    100 mA

    5

    25

    2 ÷ 8

    10

    A3100HBP
    New

    A3100HBP

    1

    Brass hexagon head bolt

    5

    4

    600 W

    100 mA

    10

    50

    8 ÷ 14

    10

    A3006

    A3006

    6

    APP 1317G4

    5

    4

    90 W

    10 mA

    10

    6

    4 ÷ 16

    20

    A3016B

    A3016B

    6

    Brass hexagon head bolt

    5

    4

    90 W

    10 mA

    5

    16

    2 ÷ 8

    20

    A3100B

    A3100B

    1

    Brass hexagon head bolt

    5

    4

    600 W

    100 mA

    5

    100

    2 ÷ 8

    10

    Technical Specifications

    Close

    No. of Channels

    1

    Polarity

    Reversible

    Output Voltage

    2 ÷ 8 V (connector output)

    Max. Output Current

    100 A

    Voltage Set/Monitor Resolution

    10 mV

    Current Set/Monitor Resolution

    100 mA

    VMAX hardware

    2 ÷ 8 V

    VMAX software

    2 ÷ 8 V

    VMAX software resolution

    5 m V

    Voltage Ripple

    < 10 mV pp (@ full load)

    Voltage Monitor vs. Output Voltage Accuracy

    max. ±50 mV ±0.3% of reading

    Voltage Set vs. Output Voltage Accuracy

    max. ±50 mV ±0.3% of reading

    Current Monitor vs. Output Current Accuracy

    ± 1A ± 2% of reading

    Current Set vs. Output Current Accuracy

    ± 1A ± 2% of reading

    Load Regulation

    ± 0.3 % (with sense wires)± 2 % (without sense wires/LDR ON/SENSE OFF)

    Test set up

    cable: length = 30m; diam.= 8mm (for both output and return) with sense wires connected
    test load: >600W
    load capacitance: 10µF electrolytic // 100nF ceramic (// to the load)

    Output Power

    600 W

    Weight

    6.5kg

    Footer

    CAEN - Tools for Discovery Logo (RGB)

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.500€ | CDU A47Ø7H7

    CAEN Group logo (B&W)
    IMQ Certification
    Cyber Essentials Plus

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Resources

    • Documentation
    • Accessibility Statement
    • Special Offers

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Support

    • Getting Started with MyCAEN Portal
    • Login / Register
    • Wishlist

    News

    • News

    Contact Us

    • Contact
    • Privacy Policy
    • Cookie Policy
    • Whistleblowing

    Copyright © 2026 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕