<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>You searched for DT14 - CAEN - Tools for Discovery</title>
	<atom:link href="https://www.caen.it/search/DT14/feed/rss2/" rel="self" type="application/rss+xml" />
	<link>https://www.caen.it/</link>
	<description></description>
	<lastBuildDate>Mon, 16 Feb 2026 13:42:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.1</generator>
	<item>
		<title>DT1419ET</title>
		<link>https://www.caen.it/products/dt1419et/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:27 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/dt1419et/</guid>

					<description><![CDATA[<p><img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" fetchpriority="high" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-250x208.jpg 250w" sizes="(max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1419ET</b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±500V</b> max voltage and a <b>200 µA</b> max current. The output polarity is independently selectable for each channel.<br />
Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷50 V/s in 1 V/s steps. The module features 5 nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 500 pA.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>Radiall R317580 HV coaxial connector for Mod.DT1419ET</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0</b> or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">warning when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>L'articolo <a href="https://www.caen.it/products/dt1419et/">DT1419ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-250x208.jpg 250w" sizes="(max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1419ET</b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±500V</b> max voltage and a <b>200 µA</b> max current. The output polarity is independently selectable for each channel.
Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷50 V/s in 1 V/s steps. The module features 5 nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 500 pA.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

Radiall R317580 HV coaxial connector for Mod.DT1419ET</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0</b> or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">warning when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div><p>L'articolo <a href="https://www.caen.it/products/dt1419et/">DT1419ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DT1470ET</title>
		<link>https://www.caen.it/products/dt1470et/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:27 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/dt1470et/</guid>

					<description><![CDATA[<p><img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1470ET</b> provides <b>4</b> independent High Voltage channels in a desktop package (110/220V AC Powered). Each channel can provide a <b>±8 kV</b> max voltage, a <b>3 mA</b> max current and a 9 W max power (8 W max power when output voltage is larger than ±3 kV). The output polarity is independently selectable for each channel.<br />
Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 50 nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 5nA.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>Radiall R317580 HV coaxial connector for DT1470ET</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>L'articolo <a href="https://www.caen.it/products/dt1470et/">DT1470ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-1-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1470ET</b> provides <b>4</b> independent High Voltage channels in a desktop package (110/220V AC Powered). Each channel can provide a <b>±8 kV</b> max voltage, a <b>3 mA</b> max current and a 9 W max power (8 W max power when output voltage is larger than ±3 kV). The output polarity is independently selectable for each channel.
Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 50 nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 5nA.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

Radiall R317580 HV coaxial connector for DT1470ET</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div><p>L'articolo <a href="https://www.caen.it/products/dt1470et/">DT1470ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DT1471ET</title>
		<link>https://www.caen.it/products/dt1471et/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:28 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/dt1471et/</guid>

					<description><![CDATA[<p><img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1471ET </b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±5.5 kV</b> max voltage and a <b>300 µA</b> max current. The output polarity is independently selectable for each channel. Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 5nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 500 pA.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>Radiall R317580 HV coaxial connector for DT1471ET</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>L'articolo <a href="https://www.caen.it/products/dt1471et/">DT1471ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-2-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The CAEN <b>Mod. DT1471ET </b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±5.5 kV</b> max voltage and a <b>300 µA</b> max current. The output polarity is independently selectable for each channel. Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 5nA Iset/Imon resolution. Zoom (x 10) for Imon increases resolution to 500 pA.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

Radiall R317580 HV coaxial connector for DT1471ET</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div><p>L'articolo <a href="https://www.caen.it/products/dt1471et/">DT1471ET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DT1471HET</title>
		<link>https://www.caen.it/products/dt1471het/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:28 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/dt1471het/</guid>

					<description><![CDATA[<p><img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The <b>Mod. DT1471HET</b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±5.5 kV</b> max voltage and a <b>20µA</b> max current. The output polarity is independently selectable for each channel. Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 1 nA Iset/Imon resolution. Zoom for Imon increases resolution to 50 pA.<br />
Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>Radiall R317580 HV coaxial connector for DT1471HET</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.<b></b></p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>L'articolo <a href="https://www.caen.it/products/dt1471het/">DT1471HET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="600" height="500" src="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3.jpg 600w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3-72x60.jpg 72w, https://www.caen.it/wp-content/uploads/2017/10/DT14XXET_p-3-250x208.jpg 250w" sizes="auto, (max-width: 600px) 100vw, 600px" />The <b>Mod. DT1471HET</b> provides <b>4</b> independent High Voltage channels in a Desktop package (110/220V AC Powered). Each channel can provide a <b>±5.5 kV</b> max voltage and a <b>20µA</b> max current. The output polarity is independently selectable for each channel. Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 1 nA Iset/Imon resolution. Zoom for Imon increases resolution to 50 pA.
Module control can take place either <b>locally </b>thanks to a <b>2.8" Touchscreen Graphic color LCD display</b> with a completely redesigned user interface or <b>remotely</b>, via <b>USB 2.0 </b>or <b>Ethernet</b>.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

Radiall R317580 HV coaxial connector for DT1471HET</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.<b></b>

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div><p>L'articolo <a href="https://www.caen.it/products/dt1471het/">DT1471HET</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EPICS IOC (PSM Power Supply Modules)</title>
		<link>https://www.caen.it/products/epics-ioc-psm-power-supply-modules/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:32 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/epics-ioc-psm-power-supply-modules/</guid>

					<description><![CDATA[<p><img width="300" height="279" src="https://www.caen.it/wp-content/uploads/2017/10/EPICS1.png" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/EPICS1.png 300w, https://www.caen.it/wp-content/uploads/2017/10/EPICS1-65x60.png 65w, https://www.caen.it/wp-content/uploads/2017/10/EPICS1-250x233.png 250w" sizes="auto, (max-width: 300px) 100vw, 300px" /><b>EPICS</b> (<b>Experimental Physics and Industrial Control System</b>) is a set of Open Source software tools, libraries and applications developed collaboratively and used worldwide to create distributed soft real-time control systems for scientific instruments such as a particle accelerators, telescopes and other large scientific experiments.<br />
Client software (EPICS Channel Access Client), which requests access to a Process Variable, runs on the Host PC and is connected to the system via TCP/IP.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><b>Supported Products:</b></td>
<td><a href="https://www.caen.it/subfamilies/up-to-8-kv-ndt14xx-n14xxet-n14xx-reversible-polarity/">NDT14xx</a>, <a href="https://www.caen.it/products/r1472ets/">R14xxET</a>, <a href="https://www.caen.it/products/dt1470et/">DT14xxET</a>, <a href="https://www.caen.it/subfamilies/up-to-8-kv-ndt14xx-n14xxet-n14xx-reversible-polarity/">N14xxET</a>, N14xx Power Supply Families</td>
</tr>
<tr>
<td><b>Supported Comm. Interface:</b></td>
<td>Ethernet, USB</td>
</tr>
</tbody>
</table>
<p>For more information about EPICS visit the <a href="https://www.anl.gov/">Argonne National Laboratory</a> EPICS website: <a class="orange" href="http://www.aps.anl.gov/epics/"><u>http://www.aps.anl.gov/epics/</u></a></p>
<p>L'articolo <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS IOC (PSM Power Supply Modules)</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="300" height="279" src="https://www.caen.it/wp-content/uploads/2017/10/EPICS1.png" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/EPICS1.png 300w, https://www.caen.it/wp-content/uploads/2017/10/EPICS1-65x60.png 65w, https://www.caen.it/wp-content/uploads/2017/10/EPICS1-250x233.png 250w" sizes="auto, (max-width: 300px) 100vw, 300px" /><b>EPICS</b> (<b>Experimental Physics and Industrial Control System</b>) is a set of Open Source software tools, libraries and applications developed collaboratively and used worldwide to create distributed soft real-time control systems for scientific instruments such as a particle accelerators, telescopes and other large scientific experiments.
Client software (EPICS Channel Access Client), which requests access to a Process Variable, runs on the Host PC and is connected to the system via TCP/IP.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><b>Supported Products:</b></td>
<td><a href="https://www.caen.it/subfamilies/up-to-8-kv-ndt14xx-n14xxet-n14xx-reversible-polarity/">NDT14xx</a>, <a href="https://www.caen.it/products/r1472ets/">R14xxET</a>, <a href="https://www.caen.it/products/dt1470et/">DT14xxET</a>, <a href="https://www.caen.it/subfamilies/up-to-8-kv-ndt14xx-n14xxet-n14xx-reversible-polarity/">N14xxET</a>, N14xx Power Supply Families</td>
</tr>
<tr>
<td><b>Supported Comm. Interface:</b></td>
<td>Ethernet, USB</td>
</tr>
</tbody>
</table>
For more information about EPICS visit the <a href="https://www.anl.gov/">Argonne National Laboratory</a> EPICS website: <a class="orange" href="http://www.aps.anl.gov/epics/"><u>http://www.aps.anl.gov/epics/</u></a><p>L'articolo <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS IOC (PSM Power Supply Modules)</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LabVIEW Driver (PSM &#8211; Power Supply Modules)</title>
		<link>https://www.caen.it/products/labview-driver-psm-power-supply-modules/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:33 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/labview-driver-psm-power-supply-modules/</guid>

					<description><![CDATA[<p><img width="357" height="359" src="https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1.png" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1.png 357w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-150x150.png 150w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-60x60.png 60w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-250x250.png 250w" sizes="auto, (max-width: 357px) 100vw, 357px" /><b>LabVIEW Driver (PSM – Power Supply Modules) </b> is a set of VIs developed to configure and monitor all the parameters of remotely controlled CAEN <b>Power Supply Modules</b>. Functions are divided in five primary groups: <b>Initialize/Close, Configuration, Action/Status, Data</b> and <b>Utility</b> to help the user to develop a control SW in the easiest possible way. All the VIs belonging to each of these primary groups are described in detail in the User Manual.<br />
A <b>Demo control SW</b> developed using this tool can be downloaded from the website, in a package containing an executable and the source code, as an example showing the capabilities of this set of VIs.</p>
<p>This Driver is also available in the relative section of the National Instruments website.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><b>Supported Operating Systems</b></td>
<td>Windows (32-64 bit)</td>
</tr>
<tr>
<td><b>Supported Products</b></td>
<td>NIM &amp; NIM/Desktop &amp; Desktop &amp; Rack Mount Power Supply Modules: SMART HV, DT55xxE, N14xx, N14xxET , NDT14xx, R14xxET and DT14xxET Families,<br />
<b></b> DT55xxE family</td>
</tr>
<tr>
<td><b>Supported Comm. Interface:</b></td>
<td>USB (N14xx / NDT14xx / N14xxET / DT14xxET / R14xxET / DT55xxE/ SMART HV), Ethernet (NDT14xx / N14xxET / DT14xxET / R14xxET/ DT55xxE/ SMART HV)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>L'articolo <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW Driver (PSM &#8211; Power Supply Modules)</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="357" height="359" src="https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1.png" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1.png 357w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-150x150.png 150w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-60x60.png 60w, https://www.caen.it/wp-content/uploads/2017/10/caen_labview-1-250x250.png 250w" sizes="auto, (max-width: 357px) 100vw, 357px" /><b>LabVIEW Driver (PSM – Power Supply Modules) </b> is a set of VIs developed to configure and monitor all the parameters of remotely controlled CAEN <b>Power Supply Modules</b>. Functions are divided in five primary groups: <b>Initialize/Close, Configuration, Action/Status, Data</b> and <b>Utility</b> to help the user to develop a control SW in the easiest possible way. All the VIs belonging to each of these primary groups are described in detail in the User Manual.
A <b>Demo control SW</b> developed using this tool can be downloaded from the website, in a package containing an executable and the source code, as an example showing the capabilities of this set of VIs.

This Driver is also available in the relative section of the National Instruments website.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><b>Supported Operating Systems</b></td>
<td>Windows (32-64 bit)</td>
</tr>
<tr>
<td><b>Supported Products</b></td>
<td>NIM &amp; NIM/Desktop &amp; Desktop &amp; Rack Mount Power Supply Modules: SMART HV, DT55xxE, N14xx, N14xxET , NDT14xx, R14xxET and DT14xxET Families,
<b></b> DT55xxE family</td>
</tr>
<tr>
<td><b>Supported Comm. Interface:</b></td>
<td>USB (N14xx / NDT14xx / N14xxET / DT14xxET / R14xxET / DT55xxE/ SMART HV), Ethernet (NDT14xx / N14xxET / DT14xxET / R14xxET/ DT55xxE/ SMART HV)</td>
</tr>
</tbody>
</table>
&nbsp;<p>L'articolo <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW Driver (PSM &#8211; Power Supply Modules)</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>N1419</title>
		<link>https://www.caen.it/products/n1419/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:34 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/n1419/</guid>

					<description><![CDATA[<p><img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1419</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1419A and N1419B) are also available. Each channel can provide a <b>±500 V</b> max voltage, a <b>200 µA</b> max current. The output polarity is independently selectable for each channel.</p>
<p>Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.<br />
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷50 V/s in 1 V/s steps. The module features 5 nA Iset/Imon resolution. Features include Imon Zoom, increasing resolution to 500 pA.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>NIM single width, 4 channels for Mod. N1419, N1419B (1 Ch), N1419A (2 Ch)</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.</p>
<p>A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 1V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:</p>
<p><b>Special versions available:</b></p>
<ul>
<li>2 channels version <strong>(N1419A)</strong></li>
<li>1 channel version <strong>(N1419B)</strong></li>
<li>2U NIM module with 220 V/110 Vac plug for desktop operation, equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> (<a href="https://www.caen.it/products/ndt1419/"><b>NDT1419</b></a>)</li>
<li>2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> <strong>(<a href="https://www.caen.it/products/n1419et/">N1419ET</a>)</strong></li>
</ul>
<p><b>Available Options:</b></p>
<ul>
<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
<p>N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a></p>
<p>L'articolo <a href="https://www.caen.it/products/n1419/">N1419</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1419_ALL-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1419</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1419A and N1419B) are also available. Each channel can provide a <b>±500 V</b> max voltage, a <b>200 µA</b> max current. The output polarity is independently selectable for each channel.

Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷50 V/s in 1 V/s steps. The module features 5 nA Iset/Imon resolution. Features include Imon Zoom, increasing resolution to 500 pA.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

NIM single width, 4 channels for Mod. N1419, N1419B (1 Ch), N1419A (2 Ch)</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.

A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 1V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">Programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:

<b>Special versions available:</b>
<ul>
 	<li>2 channels version <strong>(N1419A)</strong></li>
 	<li>1 channel version <strong>(N1419B)</strong></li>
 	<li>2U NIM module with 220 V/110 Vac plug for desktop operation, equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> (<a href="https://www.caen.it/products/ndt1419/"><b>NDT1419</b></a>)</li>
 	<li>2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> <strong>(<a href="https://www.caen.it/products/n1419et/">N1419ET</a>)</strong></li>
</ul>
<b>Available Options:</b>
<ul>
 	<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a><p>L'articolo <a href="https://www.caen.it/products/n1419/">N1419</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>N1470</title>
		<link>https://www.caen.it/products/n1470/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:34 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/n1470/</guid>

					<description><![CDATA[<p><img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1470_all.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="N1470_all" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1470_all.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1470_all-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1470_all-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1470</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1470A and N1470B) are also available. Each channel can provide a <b>±8kV</b> max voltage, a <b>3 mA</b> max current and a 9 W max power (8 W max power when output voltage is larger than ±3 kV). The output polarity is independently selectable for each channel.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>NIM single width, 4 channels for Mod. N1470, N1470B (1 Ch), N1470A, N1470AL, N1470AR (2 Ch)</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.<br />
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 50nA Iset/Imon resolution. Features include Imon Zoom, increasing resolution to 5 nA.</p>
<p>Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.</p>
<p>A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">when a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.</td>
</tr>
<tr>
<td class="text-center"><b>VMAX<br />
</b></td>
<td class="text-center">programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM8301 crate:</p>
<p><b>Special versions available:</b></p>
<ul>
<li>2 channels version <strong>(N1470A)</strong></li>
<li>1 channel version<strong> (N1470B)</strong></li>
<li>2 channels Low Cost version only locally controllable<strong> (N1470AL)</strong></li>
<li>2 channels Low Cost version only remotely controllable<strong> (N1470AR)</strong></li>
<li>4 channels, 2U NIM module with 220/110 Vac plug for desktop operation equipped with <b>2.8" Touchscreen, Ethernet </b>and <b>USB interface </b><strong>(<a href="https://www.caen.it/products/ndt1470/">NDT1470</a>)</strong></li>
<li>4 channels, 2U NIM module equipped with <b>2.8" Touchscreen, Ethernet </b>and <b>USB interface </b>(<a href="https://www.caen.it/products/n1470et/"><b>N1470ET</b></a>)</li>
</ul>
<p><b>Available Options:</b></p>
<ul>
<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
<p>N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a></p>
<p>L'articolo <a href="https://www.caen.it/products/n1470/">N1470</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1470_all.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="N1470_all" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1470_all.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1470_all-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1470_all-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1470</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1470A and N1470B) are also available. Each channel can provide a <b>±8kV</b> max voltage, a <b>3 mA</b> max current and a 9 W max power (8 W max power when output voltage is larger than ±3 kV). The output polarity is independently selectable for each channel.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

NIM single width, 4 channels for Mod. N1470, N1470B (1 Ch), N1470A, N1470AL, N1470AR (2 Ch)</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 50nA Iset/Imon resolution. Features include Imon Zoom, increasing resolution to 5 nA.

Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.

A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">when a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.</td>
</tr>
<tr>
<td class="text-center"><b>VMAX
</b></td>
<td class="text-center">programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM8301 crate:

<b>Special versions available:</b>
<ul>
 	<li>2 channels version <strong>(N1470A)</strong></li>
 	<li>1 channel version<strong> (N1470B)</strong></li>
 	<li>2 channels Low Cost version only locally controllable<strong> (N1470AL)</strong></li>
 	<li>2 channels Low Cost version only remotely controllable<strong> (N1470AR)</strong></li>
 	<li>4 channels, 2U NIM module with 220/110 Vac plug for desktop operation equipped with <b>2.8" Touchscreen, Ethernet </b>and <b>USB interface </b><strong>(<a href="https://www.caen.it/products/ndt1470/">NDT1470</a>)</strong></li>
 	<li>4 channels, 2U NIM module equipped with <b>2.8" Touchscreen, Ethernet </b>and <b>USB interface </b>(<a href="https://www.caen.it/products/n1470et/"><b>N1470ET</b></a>)</li>
</ul>
<b>Available Options:</b>
<ul>
 	<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a><p>L'articolo <a href="https://www.caen.it/products/n1470/">N1470</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>N1471</title>
		<link>https://www.caen.it/products/n1471/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:35 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/n1471/</guid>

					<description><![CDATA[<p><img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1471-1.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1471-1.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1471-1-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1471-1-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1471</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1471A and N1471B) are also available. Each channel can provide a <b>±5.5kV</b> / <b>300 µA</b> output. The output polarity is independently selectable for each channel.</p>
<p>Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.<br />
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1В500 V/s in 1 V/s steps. The module features 5nA Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 500pA.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>NIM single width, 4 channels for Mod. N1471 (2 Ch for N1471A, 1 Ch for N1471B)</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">when a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.</td>
</tr>
<tr>
<td class="text-center"><b>VMAX<br />
</b></td>
<td class="text-center">programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:</p>
<p><b>Special versions available:</b></p>
<ul>
<li>2 channels version (<strong>N1471A)</strong></li>
<li>1 channel version (<strong>N1471B</strong>)</li>
<li>4 channels, 2U NIM module with 220/110 Vac plug for desktop operation, equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/ndt1471/">NDT1471</a>)</li>
<li>4 channels, 2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> (<a href="https://www.caen.it/products/n1471et/">N1471ET</a>)</li>
<li>High-resolution models: 20µA max output, Iset/Imon: 1 nA, optional Imon-Zoom: 50 pA (<a class="orange" href="http://www.caen.it/products/n1471h/"><u>N1471H</u></a>, <a class="orange" href="http://www.caen.it/products/ndt1471h/"><u>NDT1471H</u></a> and <a class="orange" href="http://www.caen.it/products/n1471het/"><u>N1471HET</u></a>)</li>
</ul>
<p><b>Available Options:</b></p>
<ul>
<li>A1480 DC Input Power Equalizer.</li>
<li>x 10 Imon Zoom, increasing Imon resolution to 500 pA.</li>
</ul>
<p>N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page </a>or at <a href="http://www.ftdichip.com">www.ftdichip.com</a></p>
<p>L'articolo <a href="https://www.caen.it/products/n1471/">N1471</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1471-1.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1471-1.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1471-1-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1471-1-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1471</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1471A and N1471B) are also available. Each channel can provide a <b>±5.5kV</b> / <b>300 µA</b> output. The output polarity is independently selectable for each channel.

Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.
The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1В500 V/s in 1 V/s steps. The module features 5nA Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 500pA.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

NIM single width, 4 channels for Mod. N1471 (2 Ch for N1471A, 1 Ch for N1471B)</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>. A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">when a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.</td>
</tr>
<tr>
<td class="text-center"><b>VMAX
</b></td>
<td class="text-center">programmable VMAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:

<b>Special versions available:</b>
<ul>
 	<li>2 channels version (<strong>N1471A)</strong></li>
 	<li>1 channel version (<strong>N1471B</strong>)</li>
 	<li>4 channels, 2U NIM module with 220/110 Vac plug for desktop operation, equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/ndt1471/">NDT1471</a>)</li>
 	<li>4 channels, 2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface</b> (<a href="https://www.caen.it/products/n1471et/">N1471ET</a>)</li>
 	<li>High-resolution models: 20µA max output, Iset/Imon: 1 nA, optional Imon-Zoom: 50 pA (<a class="orange" href="http://www.caen.it/products/n1471h/"><u>N1471H</u></a>, <a class="orange" href="http://www.caen.it/products/ndt1471h/"><u>NDT1471H</u></a> and <a class="orange" href="http://www.caen.it/products/n1471het/"><u>N1471HET</u></a>)</li>
</ul>
<b>Available Options:</b>
<ul>
 	<li>A1480 DC Input Power Equalizer.</li>
 	<li>x 10 Imon Zoom, increasing Imon resolution to 500 pA.</li>
</ul>
N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page </a>or at <a href="http://www.ftdichip.com">www.ftdichip.com</a><p>L'articolo <a href="https://www.caen.it/products/n1471/">N1471</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>N1471H</title>
		<link>https://www.caen.it/products/n1471h/</link>
		
		<dc:creator><![CDATA[zaki]]></dc:creator>
		<pubDate>Wed, 04 Oct 2017 16:19:35 +0000</pubDate>
				<guid isPermaLink="false">http://www.caen.it/products/n1471h/</guid>

					<description><![CDATA[<p><img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1471H.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1471H.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1471H-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1471H-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1471H</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1471HA and N1471HB) are also available. Each channel can provide a <b>±5.5kV</b> / <b>20 µA</b> output. The output polarity is independently selectable for each channel.</p>
<p>Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.</p>
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong></p>
<p>NIM single width, 4 channels for Mod. N1471H, N1471HA (2 Ch), N1471HB (1 Ch)</td>
</tr>
</tbody>
</table>
<p>Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.</p>
<p>The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 1nA Iset/Imon resolution. <b> Zoom</b> for Imon increases resolution to 50 pA. Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.</p>
<p>A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.</p>
<p>Safety features allows the module to perform as a current generator and includes:<b></b></p>
<p><!-- BEGIN COMPONENT --></p>
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels<br />
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX<br />
</b></td>
<td class="text-center">programmable MAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
<p>Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:</p>
<p><b>Special versions available:</b></p>
<ul>
<li>2 channels version  (<strong>N1471HA)</strong></li>
<li>1 channel version (<strong>N1471HB</strong>)</li>
<li>2U NIM module with 220/110 Vac plug for desktop operation equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/ndt1471h/"><b>NDT1471H</b></a>)</li>
<li>2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/n1471het/"><b>N1471HET</b></a>)</li>
</ul>
<p><b>Available Options:</b></p>
<ul>
<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
<p>N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a></p>
<p>L'articolo <a href="https://www.caen.it/products/n1471h/">N1471H</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></description>
										<content:encoded><![CDATA[<img width="408" height="389" src="https://www.caen.it/wp-content/uploads/2017/10/N1471H.jpg" class="attachment-post-thumbnail size-post-thumbnail wp-post-image" alt="" decoding="async" loading="lazy" srcset="https://www.caen.it/wp-content/uploads/2017/10/N1471H.jpg 408w, https://www.caen.it/wp-content/uploads/2017/10/N1471H-63x60.jpg 63w, https://www.caen.it/wp-content/uploads/2017/10/N1471H-250x238.jpg 250w" sizes="auto, (max-width: 408px) 100vw, 408px" />The CAEN <b>Mod. N1471H</b> provides <b>4</b> independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1471HA and N1471HB) are also available. Each channel can provide a <b>±5.5kV</b> / <b>20 µA</b> output. The output polarity is independently selectable for each channel.

Channels have <a href="https://www.caen.it/faq/power-supply-grounding/">common floating return</a> (common return insulated from the crate ground); HV outputs are delivered through SHV connectors.
<table class="table table1 table1-big-bottom">
<tbody>
<tr>
<td><img class="aligncenter" src="https://www.caen.it/wp-content/uploads/2017/10/shv.png" width="32" height="77" border="0" /></td>
<td><strong>SHV connector</strong>

NIM single width, 4 channels for Mod. N1471H, N1471HA (2 Ch), N1471HB (1 Ch)</td>
</tr>
</tbody>
</table>
Consult our <a href="https://www.caen.it/support-services/connectors/">connectors reference page</a> for technical information.

The HV output Ramp-up and Ramp-down rates may be selected independently for each channel in the range 1÷500 V/s in 1 V/s steps. The module features 1nA Iset/Imon resolution. <b> Zoom</b> for Imon increases resolution to 50 pA. Power supply control can be performed either <b>locally</b>, assisted by a Graphic color display or <b>remotely</b>, via <b>USB</b>, <b>RS232</b> or <b>RS485</b>, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via <b>TCP/IP</b> by the Smart Fan Unit of CAEN <a class="orange" href="http://www.caen.it/products/nim8301/" target="_blank" rel="noopener noreferrer"><u>NIM8301</u></a>.

A complete set of <b>free software Tools</b> is available to control this unit: <a href="https://www.caen.it/products/geco2020/">GECO2020</a> with user friendly GUI and <a href="https://www.caen.it/products/caen-hv-wrapper-library/">CAEN HV Wrapper library</a> for custom SW development. <a href="https://www.caen.it/products/epics-ioc-psm-power-supply-modules/">EPICS </a>and <a href="https://www.caen.it/products/labview-driver-psm-power-supply-modules/">LabVIEW</a> also supported.

Safety features allows the module to perform as a current generator and includes:<b></b>

<!-- BEGIN COMPONENT -->
<div class="ui ui-typo">
<div class="ui ui-definitions">
<div class="ui-wrapper">
<div class="ui-content">
<table class="table table1 table1-big-bottom">
<thead></thead>
<tbody>
<tr>
<td class="text-center"><strong>Channels
</strong></td>
<td class="text-center">can be enabled or disabled through the Global Interlock logic.</td>
</tr>
<tr>
<td class="text-center"><strong>Overvoltage and Undervoltage warning</strong></td>
<td class="text-center">when the output voltage differs from the programmed value by more than 2% of set value (minimum 10V).</td>
</tr>
<tr>
<td class="text-center"><b>Overcurrent detection</b></td>
<td class="text-center">if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off.</td>
</tr>
<tr>
<td class="text-center"><b>Hardware VMAX
</b></td>
<td class="text-center">programmable MAX protection limit.</td>
</tr>
<tr>
<td class="text-center"><strong>Safety Board Interlock</strong></td>
<td class="text-center">common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
Module control can take place either locally, assisted by a Graphic colour display, or remotely, via USB (1) or RS485 (1). It is also controllable via TCP/IP (2) by the Smart Fan Unit of CAEN NIM 8301 crate:

<b>Special versions available:</b>
<ul>
 	<li>2 channels version  (<strong>N1471HA)</strong></li>
 	<li>1 channel version (<strong>N1471HB</strong>)</li>
 	<li>2U NIM module with 220/110 Vac plug for desktop operation equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/ndt1471h/"><b>NDT1471H</b></a>)</li>
 	<li>2U NIM module equipped with <b>2.8" Touchscreen, Ethernet and USB interface </b>(<a href="https://www.caen.it/products/n1471het/"><b>N1471HET</b></a>)</li>
</ul>
<b>Available Options:</b>
<ul>
 	<li><a href="https://www.caen.it/products/a1480/">A1480</a> DC Input Power Equalizer.</li>
</ul>
N14xx modules are provided with a USB VCP interface and can be programmed via PC by connecting the PC USB port with the N14xx USB B-type port; the featured controller (FT232BM chip) requires a driver available on <a href="https://www.caen.it/faq/usb-driver-for-nim-n14xx-family/">this page</a> or at <a href="http://www.ftdichip.com">www.ftdichip.com</a><p>L'articolo <a href="https://www.caen.it/products/n1471h/">N1471H</a> proviene da <a href="https://www.caen.it">CAEN - Tools for Discovery</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
