Mechanics |
19” x 7U 84TE mixed crate VME64 (6 slots for 6Ux160mm boards) / NIM (5 free slots); 1U common fan unit; weight: 28kg |
Backplane |
VME64: J1/J2, VME64X J1/J2 – J1/J0/J2 Automatic daisy chain, CBLT compliant NIM: Equipped with long-life NIM connectors |
Mains input |
230 VAC or 115 VAC, 50-60 Hz |
Maximum Total Output Power |
VME64 400W NIM 150W |
Fuse |
1 External 16 A, type B/C 1 External 2 A, class T (230 VAC) |
Output power |
VME64: 50A@+5V, 1.5A@-12V, 7.5A@+12V NIM: 5 A @ ±6V 3 A @ ±12 V 1.5 A @ ±24 V |
Isolation |
CE acc. to EN 61010 |
Load Regulation |
VME64 < 10 mV for 0-100% load change @ +5 V < 15 mV for 0-100% load change @ ±12 V NIM < 0.5 % for 10-100% load change, < 0.02 % for ±10% line change |
Efficiency |
75% ÷ 85% @ 230 Vac configuration dependent |
Noise and ripple |
VME64: +5V: 100 mVpp +3.3V: 60 mVpp ±12V: 120 mVpp NIM: ±6V < 5 mVpp ±12 V < 8 mVpp ±24 V < 10 mVpp |
Power supply type |
VME64: Telkoor Compact PCI 6U 8HP 400 Watt AC power supply NIM: CAEN Mod. N8315 |